ASCO
FlowtronicD, with its direct operating solenoid regulates flow with high accuracy and short response time. The regulation parameters can be easily adjusted via a PC allowing the regulator to be set optimally for each individual application. FlowtronicD can, naturally, be used without software; flow is then set using push buttons on the regulator operation panel. The regulator has auto-tune, which automatically regulates the current to the coil for optimal regulation, as well as fault indication via LEDs on the control panel. Available with or without a display.
Pin | Description | Cable 2 m (5 wires) | Cable 5 m (6 wires) |
1 | Supply 24 V DC | brown | brown |
2 | Analogue signal, input | white | white |
3 | Earth, supply | blue | green |
| Earth, analogue control signal* |
| yellow |
4 | Analogue signal, output | black | pink |
5 | Digital output (pressure switch) | grey | grey |
Housing | Screening (EMC) | screen | screen |
Flow Max l/min Double | 500 |
---|---|
IP Class | IP65 |
Load Max | 1250 |
Max. pressure | 8 |
Power Consumption | 30 |
Response Time | 200 |
Temperature range from | 0 |
Temperature range of media from | 0 |
---|---|
Temperature range of media to | 50 |
Temperature range to | 40 |
Throughput | 5 |
Weight | 1,85 |
Voltage DC | 24 |
FlowtronicD, with its direct operating solenoid regulates flow with high accuracy and short response time. The regulation parameters can be easily adjusted via a PC allowing the regulator to be set optimally for each individual application. FlowtronicD can, naturally, be used without software; flow is then set using push buttons on the regulator operation panel. The regulator has auto-tune, which automatically regulates the current to the coil for optimal regulation, as well as fault indication via LEDs on the control panel. Available with or without a display.
Pin | Description | Cable 2 m (5 wires) | Cable 5 m (6 wires) |
1 | Supply 24 V DC | brown | brown |
2 | Analogue signal, input | white | white |
3 | Earth, supply | blue | green |
| Earth, analogue control signal* |
| yellow |
4 | Analogue signal, output | black | pink |
5 | Digital output (pressure switch) | grey | grey |
Housing | Screening (EMC) | screen | screen |
|
|
|
|
|
||
---|---|---|---|---|---|---|
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
Articles | Flow Max l/min Double | Throughput | Price | ||
---|---|---|---|---|---|
Flowtronic,G1/4",500Nl,4-20mA + displ.
Art:
60701017
Copied
|
500
|
5
|
| ||
Flowtronic,G1/4", 10-100l/min, 0-10V
Art:
60701056
Copied
|
100
|
3
|
| ||
Flowtronic,G1/4",300Nl,0-10V
Art:
60701020
Copied
|
300
|
3
|
| ||
Flowtronic,G1/4",5-50 l/min 0-10 / 4-20
Art:
60701090
Copied
|
50
|
2
|
| ||
Flowtronic,G1/4",500Nl,4-20mA
Art:
60701018
Copied
|
500
|
5
|
|
Select a variant in the list