ANDERSON NEGELE

Anderson Negele Turbidity Sensor ITM-51

ITM-51 & ITM-51R

From a diode, infrared light is radiated into the medium. The particles present in the medium reflect the incident light detected by the receiving diode (so-called backscatter method). The electronics calculate from the received signal, the relative turbidity of the medium.

The relative turbidity is given in NTU, or on the Nails calibration standard specified in "% TU" or in the EBC.

 

Suitable for pipe sizes as small as DN25 the versatility is broad and it has been used in many applications with great success. Not only does it help to optimise systems but the reduction in lost water, cleaning solutions and product allow it to quickly and effectively pay for itself, whilst continuing to streamline and save the end user money from the day that it is installed.

 

With a complete range of process connections and a remote version available there is a solution for nearly all applications where turbidity monitoring is required.

 

Application Examples:

 

  • Patented Frontflush sensor
  • Infrared back scatter technology
  • Independent to reflexions at small diameters or electro-polished surfaces
  • No colour dependency (wave length 860 nm)
  • Sapphire glass optics
  • IP69K
  • High reproducibility: ≤ 1 % of full scale
  • Switching output (switchpoint and hysteresis freely adjustable)
  • CIP/SIP – Cleaning up to 140°C for 30 minutes maximum
  • FDA and 3A (3A Tri-Clamp only) Certified
  • Infrared Backscatter Principle
  • Measuring Range > 2000 NTU (> 500 EBC)
  • Operating Pressure Max 16 Bar
  • Approvals: FDA; 3-A

Selected variant

Selected variant

Specifications

Approvals 3-A, EHEDG, FDA
IP Class IP67, IP69K
Measurement Accuracy +/-3% - 0-999NTU ; +/- 5% > 999NTU
Pressure Range Max 20
Pressure Range Min -1
Response Time 750
Supply Voltage DC Max 32
Supply Voltage DC Min 18
Temperature ambient from -10
Temperature ambient to 60
Temperature range of media from -10
Temperature range of media to 130
Weight 750

Product description

From a diode, infrared light is radiated into the medium. The particles present in the medium reflect the incident light detected by the receiving diode (so-called backscatter method). The electronics calculate from the received signal, the relative turbidity of the medium.

The relative turbidity is given in NTU, or on the Nails calibration standard specified in "% TU" or in the EBC.

 

Suitable for pipe sizes as small as DN25 the versatility is broad and it has been used in many applications with great success. Not only does it help to optimise systems but the reduction in lost water, cleaning solutions and product allow it to quickly and effectively pay for itself, whilst continuing to streamline and save the end user money from the day that it is installed.

 

With a complete range of process connections and a remote version available there is a solution for nearly all applications where turbidity monitoring is required.

 

Application Examples:

 

  • Patented Frontflush sensor
  • Infrared back scatter technology
  • Independent to reflexions at small diameters or electro-polished surfaces
  • No colour dependency (wave length 860 nm)
  • Sapphire glass optics
  • IP69K
  • High reproducibility: ≤ 1 % of full scale
  • Switching output (switchpoint and hysteresis freely adjustable)
  • CIP/SIP – Cleaning up to 140°C for 30 minutes maximum
  • FDA and 3A (3A Tri-Clamp only) Certified

Ordering information

Please refer to the images below for ordering information.

 

 

 

 

 

 

 

 

 

 

Accessories

Related products

Articles Cable Measurement Accuracy Price
+/-3% - 0-999NTU ; +/- 5% > 999NTU
standard 5,10,25m
+/-3% - 0-999NTU ; +/-5% > 999NTU

Selected variant

Select a variant in the list

Customer support
Our customer support team answers all kinds of questions.
+35314047700
Send e-mail
Do you need help?

Cookie settings for Demesne

Cookies help us improve your experience with us, so in order to be able to handle login information, offer you personalised content and for basic functionality of this website, we use some cookies.

We will never sell on any information about you. 

Necessary Cookies

These cookies are necessary for the website to work and can not be turned off in our systems. They are usually used only in response to actions you have taken in connection with a service request, for example when setting personal preferences, logging in or filling out a form.

Analysis and measurement cookies

These cookies allow us to count the number of visits and traffic sources so that we can measure and improve our website performance. They help us know which pages are more or less popular and how visitors navigate around the site. The information that these cookies collect is aggregated and therefore completely anonymous. If you do not allow these cookies, we do not know when you have visited our website.

Marketing cookies

These cookies can be added by our partners. They can use them to create a profile of you, based on your interests, to show you more relevant information. They do not store any personal information - only information about your browser and device. If you do not accept these cookies, you will have a more general and less customized user experience.

Please login or continue as a guest

To get the best deals
Login | Create account