SENSECA

Honsberg - UR1 Series Flow Switch

Paddle

The Honsberg UR1 is a simple flow switch which can easily be adjusted and also changed from normally open to normally closed. The flow switch works via a spring-supported paddle which moves according to the flow and when the specific flow is reach a magnetic reed switch is activated.

Special versions

• Plastic materials
• Weld/solder connection
• High volume OEM version
• Ex

• Switching ranges for oil or gas
• Special values
• High volume OEM version
• PVC (solder fitting)

 

  • Switching range 1,3..35 l/min
  • Water (oils, gases and aggressive media available on request)
  • G⅜" up to G2"
  • Brass or stainless steel wetted parts
  • Max pressure 25 bar

Selected variant

Selected variant

Specifications

Accuracy ±15% fs
Adjustable Switching Point L / Min Of Water 2,5..3,5 l/min
Connection G3/8" female
Contact Rating Max 50
Contact Rating Max 50
Electrical Connection 1.5m cable
Flow Max l/min Double 10
Function Normally open or normally closed (SPST)
IP Class IP65
Media Water (oil, air and aggressive media on request)
Pressure drop Approx. 0.01 bar at max. flow
Pressure Range Max 25
Temperature range of media from 20
Temperature range of media to 110
Weight 0,35
Viscosity 1
Voltage AC max 230

Measurements and connections

Technical illustrations

Product description

The Honsberg UR1 is a simple flow switch which can easily be adjusted and also changed from normally open to normally closed. The flow switch works via a spring-supported paddle which moves according to the flow and when the specific flow is reach a magnetic reed switch is activated.

Special versions

• Plastic materials
• Weld/solder connection
• High volume OEM version
• Ex

• Switching ranges for oil or gas
• Special values
• High volume OEM version
• PVC (solder fitting)

 

Ordering information

Ordering information

 

● Specify direction of flow, medium, and switching range, UR1 or switching value UR2.

● For UR2 specify normally closed (n.c.) or normally open (n.o.).

● For oils, state viscosity, temperature and designation (e.g. ISO VG 68) (enquire about range).

● For gases, state pressure (relative or absolute), temperature and medium (e.g. air) (enquire about range).

 

 

Installation

 

  • Include straight calming section of 5 x DN in inlet and outlet.
  • Include a filter if the media is dirty (use magnetic filter for ferritic components).
  • It must be ensured that the values given for voltage, current and power are not exceeded.
  • When switched on, a load must be connected in series.
  • The electrical details apply to ohmic loads. Capacitive, inductive and lamp loads must be operated using a protective circuit.
  • Standard: horizontal inwards flow; switching head not recommended underneath; other installation positions are possible; the installation position affects the switching point and range.

Accessories

Related products

Articles Accuracy Adjustable Switching Point L / Min Of Water Connection Flow Max l/min Double Pressure drop Weight Viscosity Voltage AC / DC Max Price
±15% fs
2,5..3,5 l/min
G3/8" female
10
Approx. 0.01 bar at max. flow
0,35
1
±15% fs
2,5..3,5 l/min
G3/8" female
10
Approx. 0.01 bar at max. flow
0,4
1
±15% fs
4..4,5 l/min
G1/2" female
20
Approx. 0.01 bar at max. flow
0,35
1
±15% fs
4..4,5 l/min
G1/2" female
20
Approx. 0.01 bar at max. flow
0,4
1
±15% fs
5..6 l/min
G3/4" female
40
Approx. 0.01 bar at max. flow
0,35
1
±15% fs
5..6 l/min
G3/4" female
40
Approx. 0.01 bar at max. flow
0,35
1
±15% fs
9,5..11,5 l/min
G1" female
60
Approx. 0.01 bar at max. flow
0,4
1
±15% fs
9,5..11,5 l/min
G1" female
60
Approx. 0.01 bar at max. flow
0,45
1
±15% fs
13,5..17,5 l/min
G1¼" female
80
Approx. 0.01 bar at max. flow
0,45
1
±15% fs
13,5..17,5 l/min
G1¼" female
80
Approx. 0.01 bar at max. flow
0,5
1
±15% fs
30..38 l/min
G1½" female
100
Approx. 0.01 bar at max. flow
0,55
1
±15% fs
30..38 l/min
G1½" female
100
Approx. 0.01 bar at max. flow
0,65
1
±15% fs
42..53 l/min
G2" female
150
Approx. 0.01 bar at max. flow
0,8
1
42..53 l/min
G2" female
150
0,95
1

Selected variant

Select a variant in the list

Customer support

Our customer support team answers all kinds of questions.

phone +35314047700

Send e-mail Send e-mail

Cookie settings for Demesne

Cookies help us improve your experience with us, so in order to be able to handle login information, offer you personalised content and for basic functionality of this website, we use some cookies.

We will never sell on any information about you. 

Necessary Cookies

These cookies are necessary for the website to work and can not be turned off in our systems. They are usually used only in response to actions you have taken in connection with a service request, for example when setting personal preferences, logging in or filling out a form.

Analysis and measurement cookies

These cookies allow us to count the number of visits and traffic sources so that we can measure and improve our website performance. They help us know which pages are more or less popular and how visitors navigate around the site. The information that these cookies collect is aggregated and therefore completely anonymous. If you do not allow these cookies, we do not know when you have visited our website.

Marketing cookies

These cookies can be added by our partners. They can use them to create a profile of you, based on your interests, to show you more relevant information. They do not store any personal information - only information about your browser and device. If you do not accept these cookies, you will have a more general and less customized user experience.

Please login or continue as a guest

To get the best deals
Login | Create account