SENSECA
Model RT is a turbine transmitter entirely in stainless steel with high flow capacity. It is suitable for applications where there are requirements include a high level of accuracy. The design also makes it suitable for applications with aggressive media or extreme pressure.
Accuracy | ± 1% of full setpoint |
---|---|
Connection | External thread G ½ " |
Electrical Connection | M12x1, 4-pole |
Flow Range Max | 1,1 |
Flow Range Min | 0,11 |
Function | Turbine, hall sensor |
IP Class | IP67 |
Load Max | 100 |
Number Of Pulses / L Ca | 2900 |
Output | PNP, square wave |
Power Consumption | 20 |
Pressure drop | Approx. 0.3 bar at maximum flow |
---|---|
Pressure Range Max | 250 |
Temperature range of media from | -20 |
Temperature range of media to | 85 |
Weight | 0,32 |
Viscosity Max | 5 |
Viscosity Min | 1 |
Voltage DC max | 30 |
Voltage DC min | 10 |
Model RT is a turbine transmitter entirely in stainless steel with high flow capacity. It is suitable for applications where there are requirements include a high level of accuracy. The design also makes it suitable for applications with aggressive media or extreme pressure.
|
|
|
|
|
||
---|---|---|---|---|---|---|
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
Articles | Accuracy | Connection | Electrical Connection | Flow Range Max | Flow Range Min | Function | IP Class | Load Max | Number Of Pulses / L Ca | Output | Power Consumption | Pressure drop | Pressure Range Max | Temperature range of media from | Temperature range of media to | Weight | Viscosity Max | Viscosity Min | Voltage DC max | Voltage DC min | Price | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow sensor 1/2" s.s. 0,1-1,1m3/h, PNP
Art:
RT-015AK001
Copied
|
± 1% of full setpoint
|
External thread G ½ "
|
M12x1, 4-pole
|
1,1
|
0,11
|
Turbine, hall sensor
|
IP67
|
100
|
2900
|
PNP, square wave
|
20
|
Approx. 0.3 bar at maximum flow
|
250
|
-20
|
85
|
0,32
|
5
|
1
|
30
|
10
|
| ||
Flow sensor 3/4" s.s. 0,22-2,2m3/h PN
Art:
RT-020AK002
Copied
|
± 1% of full setpoint
|
External thread G ¾ "
|
M12x1, 4-pole
|
2,2
|
0,22
|
Turbine, hall sensor
|
IP67
|
100
|
1700
|
PNP, square wave
|
20
|
Approx. 0.3 bar at maximum flow
|
250
|
-20
|
85
|
0,42
|
5
|
1
|
30
|
10
|
| ||
Flow sensor 3/4" s.s. 0,4-4m3/h, PNP,
Art:
RT-020AK004
Copied
|
± 1% of full setpoint
|
External thread G ¾ "
|
M12x1, 4-pole
|
4
|
0,4
|
Turbine, hall sensor
|
IP67
|
100
|
1100
|
PNP, square wave
|
20
|
Approx. 0.3 bar at maximum flow
|
250
|
-20
|
85
|
0,42
|
5
|
1
|
30
|
10
|
| ||
Flow sensor 3/4" s.s. 0,8-8m3/h, PNP,
Art:
RT-020AK008
Copied
|
± 1% of full setpoint
|
External thread G ¾ "
|
M12x1, 4-pole
|
8
|
0,8
|
Turbine, hall sensor
|
IP67
|
100
|
400
|
PNP, square wave
|
20
|
Approx. 0.3 bar at maximum flow
|
250
|
-20
|
85
|
0,42
|
5
|
1
|
30
|
10
|
| ||
Flow sensor 1" s.s. 1,6-16m3/h, PNP
Art:
RT-025AK016
Copied
|
± 1% of full setpoint
|
External thread G 1 "
|
M12x1, 4-pole
|
16
|
1,6
|
Turbine, hall sensor
|
IP67
|
100
|
190
|
PNP, square wave
|
20
|
Approx. 0.3 bar at maximum flow
|
250
|
-20
|
85
|
0,63
|
5
|
1
|
30
|
10
|
| ||
Flow sensor 11/2" s.s. 3,4-34m3/h, PNP
Art:
RT-040AK034
Copied
|
± 1% of full setpoint
|
External thread G 1½ "
|
M12x1, 4-pole
|
34
|
3,4
|
Turbine, hall sensor
|
IP67
|
100
|
60
|
PNP, square wave
|
20
|
Approx. 0.3 bar at maximum flow
|
250
|
-20
|
85
|
1,42
|
5
|
1
|
30
|
10
|
| ||
Flow sensor 1" s.s. 6,8-68m3/h, PNP
Art:
RT-050AK068
Copied
|
± 1% of full setpoint
|
External thread G 2 "
|
M12x1, 4-pole
|
68
|
6,8
|
Turbine, hall sensor
|
IP67
|
100
|
24
|
PNP, square wave
|
20
|
Approx. 0.3 bar at maximum flow
|
250
|
-20
|
85
|
1,92
|
5
|
1
|
30
|
10
|
| ||
Flow sensor 1/2" s.s 0,1-1,1m3/h 4-20m
Art:
RT-015AK001E
Copied
|
± 1% of full setpoint
|
External thread G ½ "
|
M12x1, 4-pole
|
1,1
|
0,11
|
Turbine, hall sensor
|
IP67
|
100
|
|
4 (0) ... 20 mA
|
20
|
Approx. 0.3 bar at maximum flow
|
250
|
-20
|
85
|
0,32
|
5
|
1
|
30
|
10
|
| ||
Flow sensor 3/4" ss 0,22-2,2m3/h 4-20m
Art:
RT-020AK002E
Copied
|
± 1% of full setpoint
|
External thread G ¾ "
|
M12x1, 4-pole
|
2,2
|
0,22
|
Turbine, hall sensor
|
IP67
|
100
|
|
4 (0) ... 20 mA
|
20
|
Approx. 0.3 bar at maximum flow
|
250
|
-20
|
85
|
0,42
|
5
|
1
|
30
|
10
|
| ||
Flow sensor 3/4" s.s 0,4-4m3/h, 4-20mA
Art:
RT-020AK004E
Copied
|
± 1% of full setpoint
|
External thread G ¾ "
|
M12x1, 4-pole
|
4
|
0,4
|
Turbine, hall sensor
|
IP67
|
100
|
|
4 (0) ... 20 mA
|
20
|
Approx. 0.3 bar at maximum flow
|
250
|
-20
|
85
|
0,42
|
5
|
1
|
30
|
10
|
| ||
Flow sensor 3/4" s.s 0,8-8m3/h, 4-20mA
Art:
RT-020AK008E
Copied
|
± 1% of full setpoint
|
External thread G ¾ "
|
M12x1, 4-pole
|
8
|
0,8
|
Turbine, hall sensor
|
IP67
|
100
|
|
4 (0) ... 20 mA
|
20
|
Approx. 0.3 bar at maximum flow
|
250
|
-20
|
85
|
0,42
|
5
|
1
|
30
|
10
|
| ||
Flow sensor 1" s.s 1,6-16m3/h, 4-20mA
Art:
RT-025AK016E
Copied
|
± 1% of full setpoint
|
External thread G 1 "
|
M12x1, 4-pole
|
16
|
1,6
|
Turbine, hall sensor
|
IP67
|
100
|
|
4 (0) ... 20 mA
|
20
|
Approx. 0.3 bar at maximum flow
|
250
|
-20
|
85
|
0,63
|
5
|
1
|
30
|
10
|
| ||
Flow sensor 11/2" s.s 3,4-34m3/h 4-20m
Art:
RT-040AK034E
Copied
|
± 1% of full setpoint
|
External thread G 1½ "
|
M12x1, 4-pole
|
34
|
3,4
|
Turbine, hall sensor
|
IP67
|
100
|
|
4 (0) ... 20 mA
|
20
|
Approx. 0.3 bar at maximum flow
|
250
|
-20
|
85
|
1,42
|
5
|
1
|
30
|
10
|
| ||
Flow sensor 2" s.s 6,8-68m3/h, 4-20mA
Art:
RT-050AK068E
Copied
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Select a variant in the list