CONTA-CLIP

Screw fuse terminals

SK, STK, STKD, SIK, SSIK

Conta-Clip offers a wide range of Fuse-disconnect terminals to suit all requirements. The latest addition to the range is the SSIK 4 and SSIK 6, these complement the SRK range of standard terminals. These terminals are made from glass-fibre re-inforced polyamide 6.6, giving the terminal a higher operating range and good stability on the rail.
  • Material polyamide 6.6
  • Temperature resistance -40ºC...+120ºC
  • Fire-resistance class V0 - SSIK
  • LED indicator
  • Pluggable cross connectores - SSIK Range

Selected variant

Selected variant

Specifications

Approvals UL, CSA, CSA US, KEMA KUR
Connections 2
Contamination degree 3
Country of origin CZ
Cross section single wire from 0,2
Cross section single wire to 4
Cross section stranded wire from 0,2
Cross section stranded wire to 4
Cross section stranded with ferrule from 0,2
Cross section stranded with ferrule to 4
Cross-Section 4
CSA test standard C22.2 No 158
CSAus test standard UL 1059
Flammability class UL94-V2
Fuse max 6,3
Fuse size 5 x 20 / 5 x 25 mm
Height TS 32 39
Height TS 35/7.5 43,5
KEMA KEUR test standard EN 60947-7-1:2009, EN 60947-7-3:2009
Length 51,4
Number of levels 1
Operating temperature from -40
Operating temperature to 105
Overvoltage category III
Pack Size 100
Plug gauge acc. EN 60 947-1 A4
Rated Current CSA 6,3
Rated current CSAus 6,3
Rated Current To UL 16
Rated impulse voltage 4
Rated wire cross section from (AWG) 22
Rated wire cross section to (AWG) 12
Rated voltage CSAus 500
Rated Voltage To UL 600
Screw size M 3
Stripping Length 9
Tariff code 85369010
Torque max 1
Torque Min 0,5
UL test standard UL 1059
Weight 11,14
Width 8
Voltage CSA 500

Product description

Features of the SSIK range Up to 140°c Two cross connect channels for plugin SQI cross connectors Hinged lever with room for spare fuse Optional LED module SSIK4 fuse sizes 5x20, 5x25 and 5x30 SSIK6 fuse sizes 6.3x25 and 6.3x32 Can be used with solid link as a disconnect terminal Two or three disconnect levers can be operated simultaneously by using the VBS connection sleeves Fuse-disconnect terminal STK 1/STK 2 The STK 1 and the STK 2 fuse-disconnect terminals are a low profile and compact shape so they take up minimal space. The hinged lever is used to hold the fuse and locks into its open position. LED status displays are available in a variety of voltage ranges. Features of the STK 1/STK 2 Combi-foot snaps on to TS 35/TS 32 or mounting foot for the TS 15 rail Connection cross-section up to 4 mm2 STK1 and STK2 hold fuses (5 x 20/5 x 25) Compact design STK2 - Two or three disconnect levers can be operated simultaneously by using the VBS connection sleeves Can be used with solid link as disconnect terminal Fused terminal SK 1 The SK 1 fused terminals are constructed with a screw cap are designed for 5 x20 fuses (without indicator) and 5 x 25-sized (with indicator). Fuses are screwed into the fused terminal via the screw cap. Status displays using LEDs, neon indicator lamps are also available for a wide variety of voltage ranges. Features of SK 1 Terminal housing PA 6.6 UL 94-V0 glass-fibre reinforced High continuous-use temperature range Fuses are screwed into the fused terminal via the screw cap Fused terminals are available with status displays for a variety of voltage ranges Fuse disconnect terminal SIK 10/SIK 10/Z This is the old version of fuse-disconnect terminals features a hinged lever that can be locked into its open position for supporting the micro-fuse. Features of the SIK 10/SIK 10/Z Combi-foot can snap on to TS 32/TS 35 rails Connection cross-section up to 10 mm2 SIK 10 holds fuses (5 x 20/5 x 25/5 x 30) SIK 10 Z holds fuses (6.3 x 32/6.3 x 25)

Accessories

Related products

Articles Additional information Approvals Country of origin Cross connect channels Cross section single wire to Cross section stranded wire to Cross section stranded with ferrule to Cross-Section CSA test standard CSAus test standard cUL test standard EAC test standard Flammability class Fuse max Fuse size GL test standard Height TS 32 Height TS 35/7.5 KEMA KEUR test standard Length Nemko test standard Number of levels Number of test pick off options Operating temperature to Pack Size Plug gauge acc. EN 60 947-1 Rated Current CSA Rated current CSAus Rated current cUL Rated Current To UL Rated impulse voltage Rated wire cross section to (AWG) Rated voltage CSAus Rated voltage cUL Rated Voltage To UL Screw size Stripping Length Torque max Torque Min UL test standard Weight Width Voltage CSA Price
UL, CSA, CSA US, KEMA KUR
CZ
4
4
4
4
C22.2 No 158
UL 1059
UL94-V2
6,3
5 x 20 / 5 x 25 mm
39
43,5
EN 60947-7-1:2009, EN 60947-7-3:2009
51,4
1
105
100
A4
6,3
6,3
16
4
12
500
600
M 3
9
1
0,5
UL 1059
11,14
8
500
UL, CSA, CSA US, KEMA KUR
CZ
4
4
4
4
C22.2 No 158
UL 1059
UL94-V2
6,3
5 x 20 / 5 x 25 mm
55,5
60
EN 60947-7-1:2009, EN 60947-7-3:2009
67
2
105
50
A4
6,3
6,3
16
4
12
500
600
M 3
9
1
0,5
UL 1059
21,4
8
500
with LED status display
UL, KEMA KUR
BG
4
4
4
4
UL94-V2
6,3
5 x 20 / 5 x 25 mm
45,5
41
EN 60947-7-3:2009
57,5
1
105
100
A4
16
12
600
M 3
9
1
0,5
UL 1059
14,28
8
with LED status display
UL, KEMA KUR
BG
4
4
4
4
UL94-V2
6,3
5 x 20 / 5 x 25 mm
45,5
41
EN 60947-7-3:2009
57,5
1
105
100
A4
16
12
600
M 3
9
1
0,5
UL 1059
14,28
8
CSA, CSA US, KEMA KUR, EAC
DE
1
10
10
10
10
C22.2 No 158
UL 1059
TR ZU 004/2011
UL94-V0
10
5 x 20 mm
62
EN 60947-7-3:2009
52
1
1
140
20
A5
4
8
M 4
12
2
1,2
33
12,2
UL, GL, cUL, KEMA KUR, NEMKO, EAC
CZ
10
10
10
10
C22.2 No 158
TR ZU 004/2011
UL94-V2
10
5 x 20 / 5 x 25 / 5 x 30 mm
IEC 60947-7-3:2002
69
73
EN 60947-7-3:2009
60
EN 60947-7-3:2002
1
105
50
A5
10
10
8
8
600
600
M 4
12
2
1,2
UL 1059
25
8

Selected variant

Select a variant in the list

Customer support
Our customer support team answers all kinds of questions.
+35314047700
Send e-mail
Do you need help?

Cookie settings for Demesne

Cookies help us improve your experience with us, so in order to be able to handle login information, offer you personalised content and for basic functionality of this website, we use some cookies.

We will never sell on any information about you. 

Necessary Cookies

These cookies are necessary for the website to work and can not be turned off in our systems. They are usually used only in response to actions you have taken in connection with a service request, for example when setting personal preferences, logging in or filling out a form.

Analysis and measurement cookies

These cookies allow us to count the number of visits and traffic sources so that we can measure and improve our website performance. They help us know which pages are more or less popular and how visitors navigate around the site. The information that these cookies collect is aggregated and therefore completely anonymous. If you do not allow these cookies, we do not know when you have visited our website.

Marketing cookies

These cookies can be added by our partners. They can use them to create a profile of you, based on your interests, to show you more relevant information. They do not store any personal information - only information about your browser and device. If you do not accept these cookies, you will have a more general and less customized user experience.

Please login or continue as a guest

To get the best deals
Login | Create account